Home>DCS>Yokogawa ISC40S-GR-T1-03 Inductive Conductivity Sensor

Hot Categories

Yokogawa ISC40S-GR-T1-03 Inductive Conductivity Sensor

Yokogawa ISC40S-GR-T1-03 Inductive Conductivity Sensor

Item NO.: 3794746

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa ISC40S-GR-T1-03 Inductive Conductivity Sensor
  • Item NO.3794746
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-15
ANALYTICAL SENSOR / PEEK BODY / 3 M CABLE

Yokogawa ISC40S-GR-T1-03 Inductive Conductivity Sensor

A toroidal conductivity sensor with PEEK construction, Pt1000 temperature element and a three-metre integral cable for demanding process analysis.

ManufacturerYokogawa
Exact modelISC40S-GR-T1-03
Product typeInductive Conductivity Sensor
01

Overview

ISC40S-GR-T1-03 is a Yokogawa ISC40S inductive conductivity sensor. Its matched toroidal coils are encapsulated so the sensing elements do not directly contact the process.

The GR construction uses glass-filled PEEK, combining erosion resistance with broad chemical resistance. Yokogawa excludes hydrofluoric acid and oxidizing concentrated acids from the normal PEEK application range.

The 03 code identifies the three-metre cable version. The sensor is designed for Yokogawa inductive conductivity analyzers and includes a Pt1000 element for temperature compensation and indication, not process-temperature control.

02

Specifications

Manufacturer Yokogawa
Exact model ISC40S-GR-T1-03
Measurement principle Inductive / toroidal conductivity
Conductivity range 0 to 2000 mS/cm at actual process temperature
Body material Glass-filled PEEK, FDA approved
Temperature element Pt1000 to IEC 751
Nominal installation factor 1.88 cm⁻¹ for PEEK sensor
Process temperature range -20 to 130 °C
Overpressure at 25 °C 0 to 20 barg for PEEK sensor
Permitted underpressure for GR suffix 0 to 0.5 barng
Cable length 3 m integral cable
Water protection IP67 to IEC 60529
03

Features

01

Large-bore toroidal design helps resist fouling in properly arranged flowing applications.

02

PEEK sensor body provides abrasion resistance and chemical resistance for compatible process media.

03

Maximum functional cable length can reach 50 m when the approved WF10 extension cable and BA10 junction box are used.

04

In-situ calibration is required for stated accuracy when clearance to the holder is less than 25 mm.

04

Applications

  • Conductivity monitoring in chemical cleaning, concentration and interface-detection duties compatible with PEEK.
  • Industrial liquid analysis where conventional contacting electrodes would be vulnerable to coating or corrosion.
  • Flow-through or immersion installations using a Yokogawa-approved adapter or fitting in compatible material.

About IndustryParts

https://www.industryparts.com/

Process chemistry and mounting geometry remain linked

IndustryParts records ISC40S-GR-T1-03 together with analyzer, wetted-material and installation details so the sensor is not reduced to a bare model number.

  • PEEK compatibility reviewed
  • Cable length retained
  • Mounting geometry recorded
IndustryParts customer support team
05

Lifecycle

  • Confirm process chemistry against PEEK compatibility before selection.
  • Keep at least 25 mm clearance where possible, or plan an in-situ calibration.
  • Use the Pt1000 signal only for compensation and indication as directed by Yokogawa.
  • Inspect the cable, sensor bore, seals and process adapter during scheduled maintenance.
06

FAQ

Q01

Is ISC40S-GR-T1-03 suitable for hydrofluoric acid?

No. Yokogawa reserves PFA-bodied TG versions for hydrofluoric acid and strongly oxidizing concentrated acids; verify the complete wetted-material requirement.

Q02

What installation evidence should accompany an ISC40S-GR-T1-03 enquiry?

Send the analyzer model, process chemistry, concentration, temperature, pressure, mounting geometry, cable route and a photo of the complete sensor label.

Q03

Can ISC40S-GR-T1-03 be extended beyond its integral cable?

Yes, within Yokogawa guidance: the functional maximum is 50 m when using the approved WF10 extension cable and BA10 junction box.

Q04

When is field calibration especially important for ISC40S-GR-T1-03?

Perform in-situ calibration when the sensor has less than 25 mm spacing from the holder or nearby conductive structure, because installation geometry changes the effective factor.

Q05

What confirms ISC40S-GR-T1-03 is ready after replacement?

Verify correct analyzer configuration, cable integrity, temperature indication, air/zero behavior, calibration response and stable conductivity in the actual process arrangement.

Enquiry Information

Send the complete ISC40S-GR-T1-03 label, quantity and destination for an exact enquiry record.

WHATSAPP / PHONE+86 18030175807