  • Profibus DP-VI Communication Module Kit
AC 800M | PROFIBUS DP-V1 MASTER | CI854A WITH TP854

ABB CI854AK01 3BSE030220R1 PROFIBUS DP-V1 Interface Kit

A CEX-bus communication kit combining the CI854A interface and TP854 baseplate for AC 800M systems.

BrandABB
ModelCI854AK01 3BSE030220R1
Product TypeAC 800M PROFIBUS DP-V1 Communication Interface Kit
01

Overview

CI854AK01 3BSE030220R1 is the ABB AC 800M PROFIBUS DP-V1 communication interface kit. The ordering identity covers the CI854A electronics and the matching TP854 baseplate, so the kit code should not be reduced to the interface-module marking during procurement.

The interface operates as a PROFIBUS master for cyclic I/O and DP-V1 services. Controller software, field-device descriptions and the existing network design remain essential parts of a controlled spare or migration decision.

02

Specs

Manufacturer ABB
Kit Designation CI854AK01
ABB Article Number 3BSE030220R1
Controller Platform AC 800M CEX bus
Fieldbus Standard PROFIBUS DP-V1
Kit Contents CI854A communication interface and TP854 baseplate
Baseplate Width 60 mm
Bus Role PROFIBUS master only
Supported Baud Rates 9.6 kbit/s to 12 Mbit/s
Maximum Network Nodes 126
Maximum Supported Slaves 124
Available Slave Addresses 2 to 125
Maximum Interfaces per AC 800M 12; a redundant pair uses two positions
Cyclic Data Limit above 1.5 Mbit/s 4000 bytes of input and output data in total
03

Features

  • DP-V1 support combines scheduled process-data exchange with acyclic access required by suitable intelligent field devices.
  • The CEX-bus format integrates fieldbus communication directly with the AC 800M controller hardware structure.
  • Redundant interface and cable arrangements can be engineered with compatible controller and slave equipment.
  • Diagnostic information and bus parameters are managed through the AC 800M engineering environment.
04

Applications

  • AC 800M control systems using PROFIBUS-connected remote I/O and field instruments.
  • Process plants that require deterministic cyclic data plus DP-V1 device services.
  • Documented replacement of an installed CI854A and TP854 assembly.
05

Lifecycle

  • ABB identifies this kit in the Limited phase with a replacement available; CI854BK01 article 3BSE069449R1 is the published successor direction.
  • Back up the Control Builder project, GSD files, slave parameters, node allocation and redundancy design before changing hardware.
  • Check controller and system-software compatibility before introducing a newer B-version interface.
  • Commission the bus from physical-layer checks through slave diagnostics, cyclic data validation and application-interlock testing.
06

FAQ

Does CI854AK01 3BSE030220R1 include the baseplate?

Yes. The kit identity covers the CI854A communication interface together with the TP854 baseplate; confirm whether a quotation is for the complete kit or a service component.

Can CI854BK01 replace CI854AK01 3BSE030220R1 without engineering work?

Do not assume a blind swap. Review AC 800M software support, firmware, redundancy, saved configuration and the plant test plan first.

Are PROFIBUS cables and connectors supplied with CI854AK01 3BSE030220R1?

The controller catalog treats network components separately, so specify the required connectors, termination and cable hardware in the enquiry.

What project data should be retained before changing CI854AK01 3BSE030220R1?

Keep the Control Builder application, hardware tree, GSD revisions, bus timing, slave parameters, diagnostics and current topology drawing.

How should a redundant CI854AK01 3BSE030220R1 installation be assessed?

Identify both interface units, their hardware and firmware levels, controller redundancy, line-redundancy arrangement and the supported field devices.

What should be sent with a request for CI854AK01 3BSE030220R1?

Provide photographs of both labels, controller type, system version, redundancy requirement, bus speed, slave count, quantity and destination.

You May Also Like