Bently Nevada 60R/CHA03-02-00 Orbit 60 Chassis
A 3U bulkhead-mount Orbit 60 chassis configuration with dual DC power input modules and no display.
Technical Summary
60R/CHA03-02-00 identifies an Orbit 60 chassis configured for bulkhead mounting, redundant DC power input and operation without a local display. The chassis provides the mechanical and backplane platform for the required Orbit 60 modules.
Current ordering structures include additional approval and functional-safety selections. Those fields should be verified from the physical chassis label and project documentation before an exact replacement is ordered.
Specifications
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Submitted Configuration | 60R/CHA03-02-00 |
| Product Family | Orbit 60 Series |
| Chassis Type | 3U bulkhead mount |
| Power Input | Dual DC power input modules |
| Display Option | No display |
| Included Core Modules | PIM, SIM, PPM and CMM |
| Power Input Modules Included | Two |
| Approval Selection | Confirm from chassis label |
| Functional-Safety Selection | Confirm from project record |
| Installation Environment | Indoor industrial monitoring cabinet |
Features
- Provides the rack backplane and module positions for an Orbit 60 protection and condition-monitoring system.
- Dual power-input architecture supports the documented chassis power arrangement.
- Bulkhead mounting supports cabinet installations where rear and front access are planned around the machine-monitoring layout.
- The no-display configuration relies on the engineered system interface and external operator or engineering tools.
Compatibility
- Use only Orbit 60 modules, power input modules and power supplies specified for the 3U chassis.
- Do not interchange 3U and 6U power input modules or power supplies.
- Confirm approval and functional-safety fields against the installed system before treating the shortened code as a complete current order number.
Replacement
- Record every installed module, slot, connector and power-supply label before removal.
- Confirm cabinet cutout, bulkhead hardware, grounding and cooling path.
- Rebuild the slot configuration exactly, then validate power redundancy, system communication, protection logic and channel outputs.
FAQ
Is 60R/CHA03-02-00 a complete current ordering string?
It captures the chassis, power-input and display selections, but current project records should also confirm the approval and functional-safety choices.
Which mounting arrangement is required for 60R/CHA03-02-00?
The 03 chassis selection is intended for a 3U bulkhead installation, so cabinet cutout, access and mounting hardware must match that design.
Can 6U power components be reused in 60R/CHA03-02-00?
No. The 3U and 6U power input modules and associated power supplies are chassis-specific and are not interchangeable.
What should be captured before replacing 60R/CHA03-02-00?
Provide the complete chassis label, front and rear photographs, slot map, module articles, power-supply labels, approval markings and safety project status.
Does 60R/CHA03-02-00 include a local display?
The 00 display selection means the system should be planned without a chassis display and with the intended external interface path.
What acceptance tests follow a 60R/CHA03-02-00 chassis exchange?
Prove both power paths, backplane communication, module recognition, protection channels, relay actions, communications and configuration restoration.
Recommended Models
| Rittal TS 8215.500 | RM-LP55 | DGD 1000-7 3029 100073029 S071831 |
| GS2FS-D5151 | DO138 | ABB SDCS-APD-2 |
| 7EX477.50-1 | KCN4WRC1 | PTB 02 ATEX 2085X |
| RS2B | 4495B | HCC-4 |
| Siemens 2KJ3510-5HA01-0HG2-Z | E-06R | CRD5107HPB |
| PL-FD113S | 140DDO84300 | 2090-XXNFMP-S25 |
| 1SAJ590000R0102 | 3500V-2EAV4D/R | Siemens 1FT6105-8AB71-1EA0 |
| GE IC660TSD021L | X20A02632 | 485OPDR RS485 |
| DPM 635-011 | ADN-100-50-A-P-A 536380 | 8804400110 |
| 1FK2204-6AF11-1MA0 | 1FK7032-5AK71-1VG0 | PTB 500-033390 |