Provides eight current-output channels for compatible final elements and signal interfaces.
Product Overview
IC200ALG326K is the K-revision execution of the IC200ALG326 VersaMax analog output module. Emerson lists the base model as an eight-channel current output module with 13-bit conversion.
The module should be selected with the installed carrier, terminal arrangement, output range, field power, channel scaling and controller release. The K suffix remains part of the exact spare identity.
Performance
Uses the documented 13-bit output architecture for commanded analog values.
Transfers channel commands and diagnostics through the VersaMax modular backplane.
Supports compact multi-loop output control when field power and load limits are correctly engineered.
Technical Details
| Manufacturer | Emerson / legacy GE Fanuc |
|---|---|
| Exact model | IC200ALG326K |
| Base catalog number | IC200ALG326 |
| Product family | VersaMax Modular I/O |
| Module function | Analog current output |
| Output count | 8 channels |
| Conversion architecture | 13 bit |
| Hardware revision | K |
| Configuration boundary | Range, scaling, field power, load and carrier termination |
System Integration
- Export the hardware configuration and record output range, engineering scaling, fail-state behavior and field power.
- Place affected loops in an approved manual or safe condition before disturbing output wiring.
- Label every conductor and shield, then confirm load resistance and polarity before energizing the replacement.
- Commission each loop with the process protected and compare commanded, measured and indicated values.
Applications
- VersaMax control of compatible valve positioners, converters and other current-command devices.
- Compact eight-loop analog output stations with controlled scaling and fail-state records.
- Revision-controlled service replacement using the original carrier and verified terminal arrangement.
FAQ
What loop evidence should accompany an IC200ALG326K enquiry?
Provide the configured range, scaling, field-power source, load resistance, safe state, carrier and complete K-revision label.
Can IC200ALG326K be replaced while output loops remain automatic?
Use an approved operations plan to place each affected loop in manual, bypass or a defined safe state before wiring changes.
How should a low IC200ALG326K output be diagnosed?
Measure the actual loop current and load resistance, check field power and wiring, then compare the command with a controlled test load.
Does the K suffix matter for IC200ALG326K?
Yes. Preserve it and confirm controller, carrier and site qualification before approving a different hardware revision.
What acceptance test is appropriate for IC200ALG326K?
Stroke or simulate every affected loop at controlled values and record commanded current, measured current and final-element response.
About IndustryParts
https://www.industryparts.com/Output-module review includes the final element
IndustryParts prepares IC200ALG326K requests with the K revision, carrier, output scaling and connected load documented.
- K revision retained
- Eight loops identified
- Safe-state plan reviewed
Recommended Models
| AM30 1028544 | 13I34-S20P2-T0D0-STBF10N-P0SU | 6001990 |
| PWR-BGA12V50W0WW | Tecsis P3297B081101 | ABB 1SVR730830R0400 |
| CAN-8DO ZSB 1.5/8 S/S/-/PE | EXR102F001 B1322 | FXPM24 |
| 60-1022-01 | PCB00259-00 | T503917002 |
| PSA/802100/F1/100 | 4100-1290 | Siemens A5E38010207 |
| IMDSI02 | ZA40 1SBN152410R8106 | 570578.9101.01 |
| 48-4103 | ABB ACH580-01-062A-4+B056 | ABB AX522 |
| K591N SFP-H10GB-CU3M 37-0961-03 | DK32/K1/S | E94AYM11 |
| PR6246/23 C3 | CTZ30 | 3000 / 1404-DM |
| ELR1ADJ | LEM-320 | SL-2000-N |