Home>DCS>Emerson PR6424/002-010 PR6424 16 mm Eddy Current Sensor

Hot Categories

Emerson PR6424/002-010 PR6424 16 mm Eddy Current Sensor

Emerson PR6424/002-010 PR6424 16 mm Eddy Current Sensor

Item NO.: 3800882

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson PR6424/002-010 PR6424 16 mm Eddy Current Sensor
  • Item NO.3800882
  • Weight0.7500 kg = 1.6535 lb = 26.4555 oz
  • CategoryDCS
  • BrandEpro
  • Creation Time2026-10-19
60 mm sleeve option with 5 m cable and LEMO termination

Emerson PR6424/002-010 PR6424 16 mm Eddy Current Sensor

A non-armored M18 × 1.5 PR6424 sensor using the longer 60 mm sleeve and a 5 m cable.

01

Product Profile

Emerson PR6424/002-010 is a 16 mm eddy-current sensor with M18 × 1.5 thread and no armor. The 2 in the mechanical group selects Cx 60 mm, producing the documented total dimension C of 72.5 mm.

Its cable group selects the adapter plug, 5 m total cable length and LEMO termination. This exact geometry and cable length must be preserved independently from the PR6424/000-030 variant.

02

Technical Data

Manufacturer
Emerson
Exact model
PR6424/002-010
Sleeve option
Cx 60 mm; total C 72.5 mm
Adapter plug
With
Total cable length
5 m
Cable end
LEMO
Sensor diameter
16 mm
Sleeve thread
M18 × 1.5
Armored cable
No
Sensitivity / linearity
4 V/mm (101.6 mV/mil), ≤ ±1.5%
Static range
±2.0 mm (0.079 in)
Dynamic range
0 to 1,000 µm (0 to 0.039 in)
Nominal center air gap
Approximately 2.7 mm (0.11 in)
Target material
Ferromagnetic steel, 42CrMo4 standard
Minimum shaft diameter
80 mm
Operating temperature
-35 to 150 °C
Protection at sensor head
10,000 hPa (145 psi) pressure resistance
Materials
Stainless-steel sleeve and PTFE cable
03

System Role

01

Non-contact eddy-current sensing avoids mechanical loading of the rotating target.

02

The PR6424 family is intended for radial and axial dynamic displacement, position, eccentricity and speed/key measurement.

03

The documented converter family and target material remain part of the calibrated measurement chain.

04

The complete six-position suffix controls mechanical and cable options and must not be shortened during procurement.

04

Compatibility & Service

  • Record the complete PR6424 suffix, converter type, target material and installed air gap.
  • Do not mix cable or connector executions merely because the sensor family matches.
  • Protect the coaxial connector and observe the documented cable bend limits during routing.
  • After replacement, confirm static gap, sensitivity, polarity and monitor-channel alarms with the approved procedure.
05

Applications

  • Steam-, gas- and hydro-turbine shaft monitoring.
  • Compressor, pump and fan vibration or position measurement.
  • Large-shaft installations requiring a 16 mm eddy-current sensor.
  • Maintenance of an existing PR6424 measurement chain with the same mechanical and cable execution.
06

FAQ

Q01What mechanical difference separates PR6424/002-010 from the 000 execution?

The 002 configuration uses Cx 60 mm and total C 72.5 mm, giving 20 mm more sleeve length than the 000 configuration.

Q02Why must the 5 m cable remain part of the PR6424/002-010 identity?

The sensor and converter form a calibrated chain; cable execution is an ordering parameter, not a generic field-wire choice.

Q03Which converter information should be supplied with PR6424/002-010?

Provide the exact converter type and configuration, output range, target material, installed gap and monitor input.

Q04What installation risk accompanies the longer sleeve?

Available insertion depth and rear clearance must be checked so the sensor can be gapped without mechanical interference.

Q05How can a spare PR6424/002-010 be verified before shutdown?

Compare the complete six-position suffix, thread, sleeve length, cable length, adapter and LEMO termination with the installed record.