Warranty: 1 year
Condition : brand new in factory sealed box
Email: sales@mvme.cn
Chat online: +86 18030175807
A Series C Mark II field-termination and mounting assembly for high-level analog output with HART.
DC-TAOX01 provides field termination and physical mounting within a Honeywell Experion Series C Mark II analog-output assembly. The paired I/O electronics perform signal processing, diagnostics and HART communication.
The completed assembly supports stable constant-current delivery, output readback, discrepancy alarming and per-channel safe-state behavior. HART device communication and open-field-wire annunciation support commissioning and maintenance.
| Parameter | Official specification |
|---|---|
| Paired I/O module | CC-PAOH01 high-level analog output with HART |
| IOTA arrangement | DC-TAOX01, non-redundant, 6-inch |
| Output channels | 16 |
| Output signal | 4-20 mA |
| Directly settable current | 0 mA or 2.9-21.1 mA |
| Maximum resistive load | 800 ohms with 22-28 VDC supply |
| Maximum compliance voltage | 16 V |
| Maximum open-circuit voltage | 22 V |
| Response | Within 1% of final value in 80 ms |
| Output ripple | Less than 100 mV peak-to-peak across a 250-ohm load |
| Temperature drift | 0.005% of full scale per °C |
| Readback accuracy | ±4% of full scale |
| Linearity / resolution | ±0.05% of full scale nominal / ±0.05% of full scale |
| Calibrated accuracy | ±0.35% of full scale at 25°C, including linearity |
The electrical values describe the complete CC-PAOH01 and DC-TAOX01 assembly, not the passive IOTA by itself.
Used for current-output field devices such as actuators, valve positioners and recording or indicating equipment in Experion process-control systems.
| Question | Answer |
|---|---|
| Where should terminal wiring be confirmed? | Use the Honeywell project drawings and the installed cabinet documentation. |
| Can a similar-looking IOTA be substituted? | No. Match the exact model and approved hardware combination. |
| Why is the catalog weight set to zero? | No reliable manufacturer weight was located for the standalone IOTA. |
| What should be checked after replacement? | Complete the approved loop, diagnostic and HART commissioning checks. |
The following models are available for sourcing inquiries. Contact us with the exact part number and required quantity.
| No. | Recommended Model | No. | Recommended Model | No. | Recommended Model |
|---|---|---|---|---|---|
| 1 | RMN5127C | 11 | MPF3-912RSL | 21 | MR18-HW |
| 2 | 75314021 | 12 | CLIOP831A | 22 | QBM81-5 |
| 3 | 036 06 | 13 | LUCA1XFU | 23 | EY-IO551F001 |
| 4 | RD112 88.B6104X | 14 | SN3101 | 24 | JAMSC-B2505 |
| 5 | 1757-SRM | 15 | 170 top2 1700100 | 25 | 3RT1035-1AK64 |
| 6 | JSE1 | 16 | CE20-I | 26 | 6ES7222-1BF32-0XB0 |
| 7 | PA-2121-1-LF 341-0502-01 | 17 | 9160/23-11-61 | 27 | MOD2-2R |
| 8 | JL325A | 18 | MTL-FS32 | 28 | MCSL-VR-MW-2L30K-230-IP64-SP |
| 9 | DM92 | 19 | DG10 60947-5-6 | 29 | 15HD 60-798-02 |
| 10 | KCD2-SCD-EX1 | 20 | GT-VBC | 30 | TE500CW12B2A1E6 |