Lenze E94AZPM0324N 9400 Multi Drive Installation Backplane
A size-matched installation backplane for the 9400 Multi Drive mechanical and DC-bus assembly.
Overview
E94AZPM0324N is an installation backplane associated with the size-3 Lenze 9400 Multi Drive axis-module arrangement. It provides the mounting and connection basis used by the designated module size in a modular drive cabinet.
The terminal N is retained as part of the exact requested identity. Final selection should follow the installed backplane label, axis-module code and cabinet documentation rather than dimensional similarity.
Specs
| Manufacturer | Lenze |
|---|---|
| Complete Model | E94AZPM0324N |
| Product Family | Servo Drives 9400 Multi Drive |
| Component Type | Installation backplane |
| Associated Size Class | 0324 / size 3 |
| Nominal Width Class | 120 mm |
| Cabinet Function | Axis-module mounting and system connection |
| Installation Context | Shared multi-drive DC-bus assembly |
| Selection Basis | Exact label and matching axis-module documentation |
Features
- Keyed physical arrangement helps maintain the intended module-to-backplane pairing.
- The backplane supports orderly integration of a modular axis within the cabinet system.
- Exact sizing preserves bus alignment and the designed installation envelope.
- A passive component identity still requires careful inspection for heat or connector damage.
Applications
- Replacement of a damaged size-3 backplane in a 9400 Multi Drive cabinet.
- New axis-module integration following the original Lenze system design.
- Maintenance work where bus alignment and module support must remain unchanged.
Lifecycle
- De-energize, isolate and discharge the complete DC-bus system before inspection.
- Photograph busbars, connectors, mounting hardware and every adjacent module label.
- Check the matching axis module and surrounding conductors for the cause of any damage.
- Verify torque, alignment, insulation clearances and protective earth before refitting the module.
FAQ
Can E94AZPM0324N be chosen only from its physical width?
No. The matching axis-module type, keyed connection arrangement, suffix and cabinet documentation must all agree.
Which module label should accompany a E94AZPM0324N enquiry?
Provide the complete 9400 axis-module code installed on the backplane and labels from the adjacent infeed or axis modules.
Does E94AZPM0324N determine drive power by itself?
No. It is an installation component; the axis module, infeed and complete DC-bus engineering define electrical performance.
What should be inspected if E94AZPM0324N shows heat damage?
Inspect contact surfaces, busbars, torque marks, insulation, axis-module connectors, cooling path and evidence of overload or arcing.
May E94AZPM0324N be worked on immediately after mains isolation?
No. Follow the drive-system discharge time, lockout procedure and verified absence-of-voltage process for the complete DC bus.
What photographs help confirm E94AZPM0324N?
Send front and side views, the full label, connector details, cabinet position and the installed module before disassembly.
Recommended Models
| VLC-651R/VLC-651RZ-K-F | KAF77/R CM71S/BR/TF/AS1H/KK | KJ1502X1-BD1 |
| PSEN cs4.1n | IM5090 IME3015BBPKG | 3AM051.6 |
| 6GK1901-1BB10-2AB0 | Schneider LRD340 | 7746FSE A7700AES4-3 |
| 15-92-32 MR21-2 | GE IC693PWR330E | Sick WLL12-B5481 |
| DR-120-24 | INT69 TM 41A 240 S10 | Trox Technik THC24-B |
| Siemens 6ES5 464-8MF21 | B50M101 | EU/3200-032-00240-0000-0000/900076878 |
| 50FCD10 | Schneider NSX 100H + TM25D | 5ST-PFB-CLX |
| GTL22 DC 03230058 | Bopp & Reuther OI 100D/G2 DN50 / PN40 | MS 400B |
| 183486001 | ABB 2CDG 110 085 R0011 | BR 0315 CL250 |
| PD-3012-2 | GSFP-1310-20-SMF | SB3990 |