Home>DCS>Mitsubishi Electric FR-F840-01800-2-60 FREQROL-F800 Inverter

Hot Categories

Mitsubishi Electric FR-F840-01800-2-60 FREQROL-F800 Inverter

Mitsubishi Electric FR-F840-01800-2-60 FREQROL-F800 Inverter

Item NO.: 3777644

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameMitsubishi Electric FR-F840-01800-2-60 FREQROL-F800 Inverter
  • Item NO.3777644
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandMitsubishi
  • Creation Time2026-09-23
FREQROL-F800 | PUMP AND FAN CONTROL | 400 V CLASS

Mitsubishi Electric FR-F840-01800-2-60 FREQROL-F800 Inverter

A FREQROL-F800 inverter execution designed for energy-conscious pump, fan and HVAC motor control.

BrandMitsubishi Electric
ModelFR-F840-01800-2-60
Product TypeFREQROL-F800 Pump and Fan Inverter
01

Overview

FR-F840-01800-2-60 is a Mitsubishi Electric FREQROL-F800 inverter reference for variable-torque pump and fan applications. The platform combines motor control with process-oriented energy and flow functions.

The full suffix, rating mode and external reactor arrangement must be checked against the installed label. Control options, network interfaces and cabinet components remain part of the complete replacement identity.

02

Specs

Manufacturer Mitsubishi Electric
Model FR-F840-01800-2-60
Product Family FREQROL-F800
Voltage Class 400 V class
Size Code 01800
Initial ND Motor Capacity 75 kW
Application Focus Pumps, fans and HVAC systems
DC Reactor Requirement Use the specified reactor arrangement for this size
Referenced Reactor FR-HEL-H75K
Configuration Check Complete suffix, duty mode and options
03

Features

  • Provides variable-torque control functions tailored to fluid and air-moving equipment.
  • Supports process feedback and energy-management strategies within the F800 platform.
  • Offers configurable I/O and communications for building or plant automation integration.
  • Allows maintenance monitoring of drive and connected-system conditions.
04

Applications

  • Large pumps in water and process systems.
  • Industrial fans, blowers and air-handling equipment.
  • Variable-flow HVAC and utility installations.
05

Lifecycle

  • Archive parameters, process setpoints and network mapping after commissioning.
  • Include the reactor, bypass components and protective devices in the spare plan.
  • Review cooling, capacitor condition and cabinet contamination during scheduled maintenance.
  • Validate flow direction, feedback scaling and process interlocks after replacement.
06

FAQ

Why must the reactor arrangement be checked for FR-F840-01800-2-60?

This power size uses a specified DC-reactor path, so the replacement scope must include correct reactor selection, wiring and installation.

Can an FR-A800 drive directly replace FR-F840-01800-2-60?

The F800 platform targets pump and fan control; process functions, parameters, options and dimensions require a complete engineering comparison.

What process information is needed for FR-F840-01800-2-60?

Provide the motor plate, pump or fan curve, operating range, feedback sensor, control mode, bypass design and network interface.

Can another FR-F840-01800 suffix replace FR-F840-01800-2-60?

Only after the regional execution, control interface, frequency specification, options and cabinet hardware have been matched.

What should be backed up before removing FR-F840-01800-2-60?

Save parameters, PID settings, sleep or multi-pump logic, I/O assignments, network configuration and protection history.

What commissioning checks follow a FR-F840-01800-2-60 exchange?

Verify motor direction, current, minimum and maximum limits, process feedback, interlocks, reactor path and stable operation across the required flow range.

You May Also Like