Siemens 6SL3000-0BE23-6DA1 36 kW Basic Line Filter
A SINAMICS basic line filter for the documented 36 kW-class booksize line-module combinations.
Product Overview
6SL3000-0BE23-6DA1 is the Siemens basic line filter used with approved SINAMICS booksize Line Modules. Its main role is attenuation of conducted interference in the 150 kHz to 30 MHz range.
For a 36 kW Active Line Module, Siemens pairs this filter with the specified line reactor or Active Interface Module. The same article also appears in approved Basic and Smart Line Module combinations, so the actual line-module type remains part of selection.
EMC performance depends on the complete installation: line-side component combination, shield bonding, cabinet layout and total cable length must follow the SINAMICS equipment manual.
Performance
Conducted-emission attenuation
Reduces line-borne interference in the frequency range addressed by the applicable EMC design.
System-level EMC support
Works with the approved reactor or Active Interface Module to meet the documented category and cable-length objectives.
Booksize integration
Fits the specified SINAMICS S120/S220 line-side architecture.
Protective-earth path
Uses dedicated PE studs that must be bonded according to the installation instructions.
Technical Details
| Manufacturer | Siemens | Exact model | 6SL3000-0BE23-6DA1 |
|---|---|---|---|
| Product designation | Basic Line Filter | Line voltage | 380 to 480 V 3 AC |
| Line frequency | 47 to 63 Hz | Rated current | 74 A |
| Power loss | 20 W | Line and load terminals | Screw terminals, 35 mm² conductor cross-section |
| PE connection | M6 screw studs | Degree of protection | IP20 |
| Suitable Active Line Module | 6SL3130-7TE23-6AA3, 36 kW class | Suitability certificate | cURus |
About IndustryParts
https://www.industryparts.com/Line filters remain part of a complete EMC chain
IndustryParts keeps the filter article, line-module identity, interface components and installation evidence together for compatibility review.
- Exact submitted model retained
- Installed-system evidence reviewed
- Quotation identity kept traceable
System Integration
Confirm the component chain
Match line module, line reactor or Active Interface Module, filter and line voltage before installation.
Build the EMC path
Follow the Siemens cabinet, shielding, bonding, separation and PE instructions without adding uncontrolled conductor length.
Commission safely
Verify terminal torque, protective earth, phase continuity and drive diagnostics before energized functional testing.
Applications
Booksize Active Line Modules
Supporting the documented 36 kW Active Line Module combination.
Basic or Smart Line Module designs
Using the filter only where the Siemens combination table approves the article.
EMC-controlled machinery
Reducing conducted line emissions through a complete engineered cabinet and cable installation.
FAQ
Can 6SL3000-0BE23-6DA1 be selected from motor power alone?
No. Identify the exact Line Module type, rating, line voltage and required reactor or Active Interface Module combination.
What EMC evidence belongs with 6SL3000-0BE23-6DA1?
Provide the line-side component list, cabinet layout, shield and PE plan, cable lengths and the target EMC category.
Does 6SL3000-0BE23-6DA1 replace an Active Interface Module?
No. In the relevant Active Line Module design, the filter works with the approved interface module or line reactor.
What installation details matter most for 6SL3000-0BE23-6DA1?
Terminal conductor size, torque, protective-earth bonding, component spacing and the prescribed shield routing all affect performance and safety.
What proves 6SL3000-0BE23-6DA1 is ready after installation?
Correct article pairing, verified PE and phase connections, documented torque, stable diagnostics and completed EMC inspection close the record.
Recommended Models
Send the complete 6SL3000-0BE23-6DA1 identity
Include requested quantity, destination and the installed-system evidence needed for compatibility review.