Siemens CP-6014 ACP 1703 Master Control Module
A SICAM telecontrol processor associated with article 6MF1113-0GA14-0AA0 for substation and remote-terminal automation.
Key Information
CP-6014 is a Siemens ACP 1703 master control processor used in SICAM telecontrol applications. It provides core system functions and supports IEC 60870-5-101/-104 communication in documented SICAM TM configurations.
The commercial hardware association is commonly identified by Siemens article 6MF1113-0GA14-0AA0 and internal identifier GC6-014. Firmware, project database and companion communication modules are central to replacement compatibility.
Functions
- Executes master control and system functions in an ACP 1703 telecontrol station.
- Coordinates process data, commands, events and communication services for the configured RTU.
- Supports IEC 60870-5-101 and IEC 60870-5-104 basic telecontrol functions with the corresponding software and modules.
- Maintains the station project and interfaces to installed communication and I/O assemblies.
Specifications
| Manufacturer | Siemens |
|---|---|
| Model | CP-6014 |
| Associated Siemens Article | 6MF1113-0GA14-0AA0 |
| Internal Identifier | GC6-014 |
| Platform | ACP 1703 / SICAM TM |
| Module Role | Master control processor |
| Telecontrol Functions | IEC 60870-5-101/-104 basic functions |
| Configuration Basis | Station project, firmware and companion modules |
| Typical Environment | Substation and utility remote-terminal automation |
| Replacement Requirement | Exact hardware and software baseline matching |
Installation
- Export the SICAM station project, protocol parameters, addresses and time-synchronization settings before removing CP-6014.
- Record the full Siemens article, hardware revision, firmware and every adjacent communication or I/O module.
- Install with station power isolated and observe the documented rack, grounding and electrostatic-discharge procedures.
- After restoration, test indications, commands, event timestamps, redundancy behavior and every control-center link.
Lifecycle
- Treat CP-6014 as a legacy telecontrol component and keep a recoverable engineering archive with the spare.
- Do not rely on processor identity alone; protocol software and station database compatibility are equally important.
- A modernization project should preserve signal mapping, time quality, command interlocks and control-center testing.
FAQ
Which Siemens article is associated with CP-6014?
CP-6014 is associated with Siemens article 6MF1113-0GA14-0AA0 and the GC6-014 identifier.
What records are essential before replacing CP-6014?
Back up the station project, protocol database, firmware, addresses, time settings and the installed module list.
Can CP-6014 be exchanged without re-testing the control center?
No. Indications, commands, timestamps and IEC 60870 links should be verified end to end after replacement.
What compatibility issue most often affects CP-6014?
A hardware match can still fail when firmware, protocol software or the engineering database does not align with the station.
What should be supplied with a CP-6014 enquiry?
Provide 6MF1113-0GA14-0AA0, the module labels, firmware, rack layout, station project version and protocol configuration.