Home>DCS>Yokogawa MG8E-5AWNS-E Flameproof Paramagnetic Oxygen Analyzer

Hot Categories

Yokogawa MG8E-5AWNS-E Flameproof Paramagnetic Oxygen Analyzer

Yokogawa MG8E-5AWNS-E Flameproof Paramagnetic Oxygen Analyzer

Item NO.: 3792245

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa MG8E-5AWNS-E Flameproof Paramagnetic Oxygen Analyzer
  • Item NO.3792245
  • Weight38.0000 kg = 83.7757 lb = 1340.4106 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-13
Exact configured execution for process oxygen analysis

Yokogawa MG8E-5AWNS-E Flameproof Paramagnetic Oxygen Analyzer

An integrated paramagnetic analyzer for continuous oxygen measurement in process gas, including flammable mixtures.

ManufacturerYokogawa
Exact modelMG8E-5AWNS-E
Product typeFlameproof Paramagnetic Oxygen Analyzer
01

Key Information

MG8E-5AWNS-E is a flameproof Yokogawa paramagnetic oxygen analyzer with integrated detector and converter. Its magnetic proportional-flow method measures oxygen selectively without exposing the sensor directly to the sample gas.

The suffix identifies a 0-5 to 0-25 vol% O2 range execution, standard cell material, nitrogen auxiliary gas at 35 ml/min, 100-115 VAC power and English language configuration.

02

Functions

01

Continuously measures oxygen concentration in gaseous mixtures, including suitable flammable-gas applications.

02

Provides an isolated 4-20 mA analog output plus configurable status, alarm and range contacts.

03

Supports remote range change and calibration-start contact inputs.

04

Offers automatic, semiautomatic or manual calibration with self-diagnostics and atmospheric-pressure compensation.

03

Specifications

Manufacturer Yokogawa
Measurement principle Paramagnetic, magnetic proportional-flow system
Configured range code 0-5 to 0-25 vol% O2; three programmable ranges
Cell material code Standard
Auxiliary gas Nitrogen
Auxiliary-gas flow code 35 ml/min
Power code 100-115 VAC, 50/60 Hz
Language code English
Analog output 4-20 mA DC; 550 ohms maximum load
Sample-gas flow 300-800 ml/min; standard set value 600 ml/min
Sample-gas inlet pressure Approximately 7 kPa
Sample-gas temperature 0 to 50 degrees C
Auxiliary-gas pressure 350-500 kPa
Ambient temperature -5 to +50 degrees C
Structure Flameproof Ex d IIB T4X
Repeatability Within plus or minus 1% of span
Linearity Within plus or minus 1% of span
Response 90% within 3 seconds after sample reaches the analyzer inlet
04

Installation

  • Handle the analyzer as a 38 kg precision instrument and protect it from impact during unpacking and mounting.
  • Install indoors on the approved panel or wall arrangement and use the specified flameproof cable glands.
  • Supply nitrogen auxiliary gas at 350-500 kPa before applying electrical power.
  • Condition the sample to the specified flow, pressure and temperature and vent it safely to atmosphere.
  • Prove zero with nitrogen and span with dry air, then verify analog and contact behavior before service.
05

Lifecycle

  • Retain the full MG8E-5AWNS-E suffix because range, cell, gas, flow, power and language are coded in the model.
  • Maintain clean sample conditioning and stable auxiliary-gas pressure to protect measurement performance.
  • Archive calibration results, interference-gas compensation settings and alarm assignments after each service event.

About IndustryParts

https://www.industryparts.com/

Analyzer suffix and gas service reviewed together

IndustryParts keeps the configured range, auxiliary-gas, power and language codes visible for MG8E-5AWNS-E supply.

  • Full suffix retained
  • Gas service documented
  • Power execution verified
IndustryParts field service support
07

FAQ

What must be supplied continuously for MG8E-5AWNS-E operation?

The analyzer requires the specified nitrogen auxiliary gas; it must be flowing at the required pressure before electrical power is applied.

Can MG8E-5AWNS-E be replaced by another MG8E suffix?

Only after every suffix field is compared. Range, cell material, auxiliary-gas condition, power and language are configuration-defining items.

What process information is needed before installing MG8E-5AWNS-E?

Provide sample composition, expected oxygen range, temperature, pressure, moisture, contaminants and the proposed sampling and vent arrangement.

What should be included in an MG8E-5AWNS-E calibration record?

Record zero and span gases, gas pressures and flow, ambient conditions, response, analog output and any interference-gas compensation adjustment.

How should MG8E-5AWNS-E be handled during maintenance?

Use suitable lifting support, preserve flameproof joints and glands, isolate power and gases, and prevent shock to the precision measuring assembly.

Enquiry Information

Send the complete MG8E-5AWNS-E label, quantity and destination for an exact enquiry record.

WHATSAPP / PHONE+86 18030175807

You May Also Like