PACSystems RX3i / Series 90-30 I/OD-Revision Eight-Point Normally Open Relay Output Module
D HARDWARE REVISION · EIGHT ISOLATED RELAYS · NORMALLY OPEN

Emerson GE Fanuc IC694MDL930D Eight-Point Isolated Relay Output Module

A D-revision execution of the IC694MDL930 isolated eight-point normally open relay output module.

01
PRODUCT CONTEXT

Product Profile

IC694MDL930D retains the D hardware-revision suffix on the IC694MDL930 relay-output base article. The module provides eight isolated, normally open relay points with a published 4 A rating.

The complete D-revision label should remain attached to the rack record and quotation. Public family data defines the base electrical role; the suffix is treated as a controlled hardware identity rather than a reason to infer unpublished differences.

02
CONTROLLED DATA

Technical Data

Manufacturer

Emerson / GE Fanuc

Exact model

IC694MDL930D

Base catalog

IC694MDL930

Hardware revision

D

I/O family

IC694 discrete output

Output points

8

Output technology

Electromechanical relay

Contact form

Normally open

Isolation

Individually isolated outputs

Published current rating

4 A

System context

PACSystems RX3i / Series 90-30

03
OPERATING ROLE

System Role

01Revision-specific identity02Eight isolated field circuits03Normally open contact action04Load-by-load engineering

Revision-specific identity

The D suffix remains visible through sourcing, receipt and installation.

Eight isolated field circuits

Each relay output is separated from the others.

Normally open contact action

Each field circuit closes only when its output is energized.

Load-by-load engineering

The terminal record can preserve different approved field circuits and suppression requirements.

04
SELECTION BOUNDARY

Compatibility

EXACT IDENTITY

IC694MDL930D

Record the complete suffix, terminal assembly and host-rack context before approving another IC694MDL930 execution.

HOST RECORD

PACSystems RX3i / Series 90-30 I/O

Retain the installed host, project and connection evidence that defines the approved use of this execution.

ACCEPTANCE

Verified field fit

Complete the model-specific checks described in the service sequence before return to operation.

05
FIELD USE

Applications

01

Revision-controlled spares

Maintaining a site that records the D execution of the IC694MDL930 base module.

02

Isolated device switching

Operating discrete field loads that require separate relay circuits.

03

Legacy rack maintenance

Restoring the documented slot and point map without altering the controller application.

ConfirmCapture the full IC694MDL930D label, rack, slot, terminal assembly and field-load schedule.ReplaceRemove all external sources, retain conductor identification and install only after the revision decision is approved.ProveTest each relay contact, connected load and associated permissive or interlock.
06
CUSTOMER QUESTIONS

FAQ

Q01

What distinguishes IC694MDL930D from the unsuffixed IC694MDL930?

IC694MDL930D explicitly records hardware revision D; the functional base remains the eight-point isolated normally open relay module.

Q02

Should the D suffix be omitted from a IC694MDL930D quotation?

No. Preserve the complete installed label so revision control is not lost.

Q03

Can another IC694 relay module replace IC694MDL930D?

Only after comparing point count, contact form, rating, isolation, terminal wiring and host-project requirements.

Q04

Which load details should accompany a IC694MDL930D request?

Provide field voltage, steady and inrush current, suppression, terminal numbers and required safe state for every used point.

Q05

What completes IC694MDL930D acceptance?

Verified contact action under the documented loads plus successful interlock and de-energization tests complete the record.

INDUSTRIAL SOURCING SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact records support a cleaner quotation

IndustryParts prepares IC694MDL930D enquiries around the complete manufacturer label, requested quantity and installed-system evidence. Share the application record that distinguishes this execution before a supply proposal is prepared.

Complete label retainedHost context reviewedQuantity linked to the enquiry