Siemens 6AG1342-5DA03-7XE0 | SIPLUS NET CP 342-5

Product Profile

6AG1342-5DA03-7XE0 is a SIPLUS NET CP 342-5 communications processor from Siemens, designed for connecting SIMATIC S7-300 PLCs to PROFIBUS networks. It is based on the standard 6GK7342-5DA03-0XE0 and features conformal coating for extended environmental protection.

The SIPLUS version is approved for an extended temperature range of -25°C to +70°C and is resistant to condensation, frost, chemically active substances, and biologically active substances in accordance with EN 60721-3-3 (Class 3C4, 3B2).

The product lifecycle (PLM) status is PM400: Phase Out Started, with the phase-out effective date since December 19, 2023.

SIPLUS Extreme PROFIBUS DP 12 Mbit/s S7-300 Conformal Coated
Key details
  • Siemens SIPLUS NET CP 342-5
  • PROFIBUS communications processor
  • For SIMATIC S7-300
  • Conformal coated version
  • PM400 Phase Out Started

Technical Data

Electrical & communication

Manufacturer Siemens
Model 6AG1342-5DA03-7XE0
Product type SIPLUS NET CP 342-5
Based on 6GK7342-5DA03-0XE0
Supply voltage 24 V DC (external)
Backplane current (5 V) 0.15 A
Power loss 6.75 W
Data rate (PROFIBUS) 9.6 kbit/s – 12 Mbit/s
PROFIBUS interface 9-pin Sub-D socket (RS485)
Country of origin Germany
Customs tariff number 85176200
RoHS compliant Since: 01.09.14

Environmental specifications

Conformal coating Yes
Operating temperature -25°C to +70°C
Storage/transport temperature -40°C to +70°C
Relative humidity 100% (including condensation/frost)
Chemical resistance Class 3C4
Biologically active substances Class 3B2
Installation altitude (max) 5000 m
Product lifecycle PM400 Phase Out Started
Phase-out effective date 19.12.23
Note: The SIPLUS version features conformal coating and is designed for harsh environments.

System Role

The 6AG1342-5DA03-7XE0 functions as a communications processor that connects the SIMATIC S7-300 PLC to a PROFIBUS network. It serves as the interface between the S7-300 backplane bus and the PROFIBUS fieldbus, enabling the CPU to communicate with distributed I/O devices, drives, operator panels, and other PROFIBUS nodes.

The CP 342-5 supports PROFIBUS DP for high-speed cyclic I/O data exchange, S5-compatible communication for integration with legacy systems, PG/OP communication for programming and operator panel connectivity, and S7 communication for data exchange between controllers.

The SIPLUS version is specifically designed for applications where standard modules cannot withstand the ambient conditions. Its conformal coating protects against condensation, frost, chemically active substances, and biologically active substances, making it suitable for harsh industrial environments.

PROFIBUS DP master S7 communication S5-compatible PG/OP communication
Architecture context
  • SIMATIC S7-300
  • PROFIBUS DP fieldbus
  • Distributed I/O network
  • Harsh environment applications

Compatibility

The 6AG1342-5DA03-7XE0 is designed for integration into Siemens SIMATIC S7-300 systems.

Compatible components

System SIMATIC S7-300
Standard version 6GK7342-5DA03-0XE0
Mounting DIN rail
PROFIBUS data rate 9.6 kbit/s – 12 Mbit/s
PROFIBUS interface 9-pin Sub-D socket (RS485)
Power supply 24 V DC external + 5 V DC backplane
Compatibility notes:
  • This module is based on the standard CP 342-5 (6GK7342-5DA03-0XE0). In hardware configuration, use the standard part number with the SIPLUS environmental extensions.
  • The module supports multiple communication protocols including PROFIBUS DP, S5-compatible, PG/OP, and S7 communication.
  • When replacing a CP 342-5, archive the STEP 7 project, CP configuration, PROFIBUS address, bus parameters, connection table, and diagnostics before replacement.
  • The product has been phased out (PM400 Phase Out Started). For new installations, consider current SIPLUS NET communication processors.

Applications

The SIPLUS CP 342-5 is deployed in industrial automation applications requiring PROFIBUS connectivity in harsh environments.

Chemical processing plants
Oil & gas installations
Power generation
Marine & offshore
Water & wastewater treatment
Mining operations
Distributed I/O networks
Drive control systems
Typical industries: Chemical, oil & gas, power generation, marine, mining, and heavy industry where SIPLUS extreme protection is required.
Key applications: The CP 342-5 is ideal for connecting S7-300 systems to PROFIBUS DP networks in environments requiring conformal coating, extended temperature range, and resistance to chemically active substances.

FAQ – Frequently Asked Questions

Q1: What is the difference between 6AG1342-5DA03-7XE0 and 6GK7342-5DA03-0XE0?

6AG1342-5DA03-7XE0 is the SIPLUS version with conformal coating for harsh environments, extended temperature range (-25°C to +70°C), and resistance to chemically and biologically active substances. 6GK7342-5DA03-0XE0 is the standard version.

Q2: What PLC system is this module compatible with?

It is compatible with SIMATIC S7-300 PLCs.

Q3: What is the product lifecycle status of 6AG1342-5DA03-7XE0?

It has been classified as PM400 Phase Out Started , with the effective phase-out date since December 19, 2023.

Q4: What data rates are supported?

The PROFIBUS interface supports data rates from 9.6 kbit/s up to 12 Mbit/s.

Q5: Is the 6AG1342-5DA03-7XE0 still in production?

No. Siemens has initiated the phase-out process (PM400). It may still be available through limited stock or legacy spare-part channels.

You May Also Like