Home>PLC>Siemens 6SL3352-6TE35-0AA3 SINAMICS Control Interface Board

Hot Categories

Siemens 6SL3352-6TE35-0AA3 SINAMICS Control Interface Board

Siemens 6SL3352-6TE35-0AA3 SINAMICS Control Interface Board

Item NO.: 3788593

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SL3352-6TE35-0AA3 SINAMICS Control Interface Board
  • Item NO.3788593
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-11
SINAMICS S | 490 A MOTOR MODULE | CONTROL INTERFACE BOARD

Siemens 6SL3352-6TE35-0AA3 SINAMICS Control Interface Board

A replacement control interface board assigned to the 380–480 V three-phase, 490 A SINAMICS motor-module execution.

BrandSiemens
Model6SL3352-6TE35-0AA3
Product TypeSINAMICS S Replacement Control Interface Board for 490 A Motor Module
01

Product Profile

6SL3352-6TE35-0AA3 is a Siemens SINAMICS S replacement Control Interface Board for a 3 AC 380–480 V, 50/60 Hz, 490 A Motor Module. It is an internal drive spare rather than a complete stand-alone Motor Module.

Selection depends on the complete 6SL3352-6TE35-0AA3 MLFB, host Motor Module nameplate, cabinet position, connectors and hardware revision. Similar 6SL3352 boards are assigned to different power classes.

02

Technical Data

Manufacturer Siemens
Model 6SL3352-6TE35-0AA3
Product Family SINAMICS S
Product Type Replacement Control Interface Board
Assigned Host SINAMICS Motor Module
Supply Class 3 AC 380–480 V
Supply Frequency 50/60 Hz
Assigned Current Class 490 A Motor Module
Component Scope Internal service board; not a complete Motor Module
Revision Boundary Complete 0AA3 suffix required
Host Evidence Motor Module MLFB, serial number and power rating
Interface Evidence Board labels, connector positions and cabinet photographs
Handling Isolation, discharge verification and ESD-controlled service
Acceptance Diagnostics, control-interface checks and controlled motor test
03

System Role

01

Carries the control-interface functions assigned to the matched high-current Motor Module.

02

Preserves the documented 490 A board execution inside the SINAMICS power architecture.

03

Connects the drive-control environment to the module power stage through the engineered internal interfaces.

04

Provides a serviceable board identity without redefining the complete Motor Module rating.

04

Compatibility

  • Match the complete 6SL3352-6TE35-0AA3 code to the host Motor Module label.
  • Compare board revision, connectors, mounting, cooling context and cabinet position.
  • Preserve the control-unit project, drive firmware and parameter set associated with the power module.
  • Do not substitute another 6SL3352 current class on visual similarity.
05

Applications

  • Service of installed SINAMICS S motor modules in high-power cabinet drives.
  • Planned board-level repair where diagnostics isolate the control-interface assembly.
  • Legacy drive support requiring exact revision and host-module traceability.
06

FAQ

Is 6SL3352-6TE35-0AA3 a complete 490 A Motor Module?

No. It is the replacement Control Interface Board assigned to that Motor Module execution, so the host power assembly remains part of the selection evidence.

What prevents a wrong 6SL3352 board from being supplied instead of 6SL3352-6TE35-0AA3?

Use the complete Motor Module and board labels, cabinet position and connector photographs; nearby order numbers cover other current classes.

Which data should be secured before removing 6SL3352-6TE35-0AA3?

Archive the drive project and parameters, diagnostics, firmware, module identity and the exact internal plug map.

How should stored energy be managed during a 6SL3352-6TE35-0AA3 exchange?

Follow the cabinet lockout procedure, observe the specified discharge time and prove the DC link de-energized before any ESD-controlled board work.

What acceptance evidence is expected after installing 6SL3352-6TE35-0AA3?

Record clean diagnostics, restored configuration, correct control signals, interlocks, cooling status and controlled motor operation under the approved load test.

You May Also Like