Home>DCS>Emerson IC695ALG608 RX3i Analog Input Module

Hot Categories

Emerson IC695ALG608 RX3i Analog Input Module

Emerson IC695ALG608 RX3i Analog Input Module

Item NO.: 3788626

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC695ALG608 RX3i Analog Input Module
  • Item NO.3788626
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-11
PACSYSTEMS RX3I | VOLTAGE/CURRENT INPUT | 8 SINGLE-ENDED OR 4 DIFFERENTIAL

Emerson IC695ALG608 RX3i Analog Input Module

A PACSystems RX3i voltage/current input module configurable for eight single-ended or four differential analog channels.

BrandEmerson
ModelIC695ALG608
Product TypeRX3i 8/4-Channel Analog Input Module
01

Product Overview

IC695ALG608 is a PACSystems RX3i analog input module for voltage and current measurements. The documented channel architecture supports eight non-isolated single-ended inputs or four differential inputs.

The module belongs to the RX3i rack-based I/O family designed for process and discrete applications with configurable I/O and diagnostics. Range selection, wiring mode and scaling must be preserved channel by channel when the module is replaced.

02

Performance

  • Supports eight single-ended input channels when the application uses the common-reference arrangement.
  • Supports four differential channels when the engineered signal path requires differential measurement.
  • Accepts voltage and current input configurations within the approved RX3i module setup.
  • Provides RX3i module diagnostics for commissioning and maintenance workflows.
  • Uses the rack-based RX3i mechanical and backplane architecture.
03

Technical Details

Manufacturer Emerson
Model IC695ALG608
Product Family PACSystems RX3i
Product Type Analog voltage/current input module
Single-Ended Inputs 8 non-isolated channels
Differential Inputs 4 channels
Signal Categories Voltage and current
Isolation Architecture Non-isolated channel architecture
Mounting Context PACSystems RX3i rack-based I/O
Agency Listing UL and UL hazardous-location listing
Approvals CE Zone 2, ATEX, Class I Division 2 and listed marine approvals
Configuration Control Record channel mode, range, scaling and diagnostics
Compatibility Control Confirm rack, controller firmware and PAC Machine Edition support
04

System Integration

  • Export every channel mode, range, scaling, filter and diagnostic setting from the approved project.
  • Record terminal positions, commons, shields, loop supplies and whether each signal is single-ended or differential.
  • Verify rack power and controller/module firmware compatibility before inserting IC695ALG608.
  • Restore wiring by checked loop schedule and keep voltage and current circuits separated from unsupported configurations.
  • Inject known signals in each configured mode and verify raw data, engineering units, alarms and controller logic.
05

Applications

  • Voltage and current acquisition in PACSystems RX3i process-control racks.
  • Eight-channel single-ended installations where the documented common-reference arrangement is appropriate.
  • Four-channel differential measurement applications requiring the approved wiring mode.
  • Revision-controlled replacement of an installed RX3i analog input module.
06

FAQ

What must be known before quoting IC695ALG608?

Provide the complete label, rack and slot, controller and firmware, PAC Machine Edition release, terminal assembly and a channel schedule showing voltage/current and single-ended/differential mode.

Can IC695ALG608 wiring mode be inferred from terminal positions alone?

No. Confirm the project configuration, channel pairing, commons and field drawing because the same module supports different channel architectures.

What is the main migration risk when replacing another RX3i analog input with IC695ALG608?

Channel count, isolation, signal range, terminal wiring, diagnostics and project configuration may differ even when the modules occupy the same rack format.

How should unused IC695ALG608 channels be handled?

Follow the approved RX3i configuration and wiring instructions for unused points; do not add field links or ranges that are absent from the validated project.

What should the IC695ALG608 acceptance test include?

Test every configured channel with a traceable voltage or current source, verify diagnostics and scaling, and retain the project checksum and loop-restoration record.

You May Also Like