Home>DCS>Emerson IC695ALG708 RX3i Analog Output Module

Hot Categories

Emerson IC695ALG708 RX3i Analog Output Module

Emerson IC695ALG708 RX3i Analog Output Module

Item NO.: 3788773

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC695ALG708 RX3i Analog Output Module
  • Item NO.3788773
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-12
PACSYSTEMS RX3I | 8 ANALOG OUTPUTS | CURRENT/VOLTAGE CONTROL

Emerson IC695ALG708 RX3i Analog Output Module

An eight-channel PACSystems RX3i analog output module for configured current and voltage control signals.

BrandEmerson
ModelIC695ALG708
Product TypeRX3i 8-Channel Analog Output Module
01

Product Overview

IC695ALG708 is a PACSystems RX3i analog output module with eight configurable current/voltage output channels. It belongs to the rack-based RX3i I/O family used in mission-critical discrete and process applications.

A replacement must preserve each channel range, scaling, fallback behavior, terminal wiring and controller reference. The module should be commissioned as part of the complete output loop rather than judged from an unloaded value alone.

02

Performance

  • Provides eight analog output channels in one RX3i rack position.
  • Supports configured current and voltage output applications.
  • Integrates with RX3i controller diagnostics and project-based channel configuration.
  • Offers the standard RX3i rack-based mechanical and backplane interface.
  • Supports process actuators and analog setpoint paths within the approved module limits.
03

Technical Details

Manufacturer Emerson
Model IC695ALG708
Product Family PACSystems RX3i
Product Type Analog current/voltage output module
Output Channels 8
Signal Categories Current and voltage
Mounting Context PACSystems RX3i rack-based I/O
Approximate Module Dimensions 34 × 145 × 140 mm
Agency Listing UL and UL hazardous-location listing
Approvals CE Zone 2, ATEX, Class I Division 2 and listed marine approvals
Configuration Control Record output range, scaling, fallback and diagnostics for every channel
Load Control Verify field load, loop power and wiring against the approved design
Compatibility Control Confirm rack, controller firmware, terminal assembly and PAC Machine Edition support
04

System Integration

  • Export channel ranges, scaling, fallback states, alarms and controller references from the approved project.
  • Record the IC695ALG708 label, terminal assembly, field loads, loop power, commons and shield terminations.
  • Place every controlled device in the approved safe state before disconnecting an output.
  • Restore each current or voltage channel from the checked loop schedule and verify polarity before enabling control.
  • Test zero, span, intermediate command, fallback behavior, alarms and final actuator response for every used channel.
05

Applications

  • Analog setpoint and command outputs in PACSystems RX3i process control.
  • Current-loop control of compatible valve, drive and instrumentation interfaces.
  • Voltage-command applications within the approved IC695ALG708 configuration.
  • Revision-controlled replacement of installed RX3i analog output hardware.
06

FAQ

What information is required for an IC695ALG708 quotation?

Provide the full label, rack and slot, controller and firmware, PAC Machine Edition release, terminal assembly and a channel list with current/voltage range, load and fallback state.

Can IC695ALG708 be replaced while actuators remain in automatic control?

Use the site-approved maintenance strategy. Outputs must be placed in a controlled safe or manual state, with fallback and process risk addressed before wiring is disturbed.

Why should an IC695ALG708 output be tested under load?

An unloaded reading does not prove loop power, field wiring, burden, polarity, actuator response or controller scaling; the complete channel needs a controlled functional test.

What should be checked if an IC695ALG708 channel reaches the wrong endpoint?

Review configured range and scaling, project reference, terminal wiring, loop power, field load, fallback configuration and actuator calibration.

Can another RX3i analog output module replace IC695ALG708 directly?

Only after channel count, signal ranges, isolation, terminal hardware, diagnostics, firmware support and the application project have been compared.

You May Also Like