Home>DCS>Emerson IC695HSC304 High-Speed Counter Module

Hot Categories

Emerson IC695HSC304 High-Speed Counter Module

Emerson IC695HSC304 High-Speed Counter Module

Item NO.: 3805183

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC695HSC304 High-Speed Counter Module
  • Item NO.3805183
  • Weight0.2000 kg = 0.4409 lb = 7.0548 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-22
PACSystems RX3iCONTROLLED PRODUCT DOSSIER
RX3I HIGH-SPEED COUNTING · FOUR COUNTERS · EIGHT INPUTS / SEVEN OUTPUTS

Emerson IC695HSC304 High-Speed Counter Module

An RX3i high-speed counter module with four configurable counters and a 1.5 MHz published count rate.

MANUFACTUREREmerson
EXACT MODELIC695HSC304
PRODUCT TYPEHigh-Speed Counter Module
Counters1 to 4
High-speed inputs8
High-speed outputs7
01
PRODUCT RECORD

Overview

Emerson IC695HSC304 is a PACSystems RX3i high-speed counter module for applications that require hardware-based counting, timing and fast discrete response.

Manufacturer documentation identifies eight high-speed inputs, seven high-speed outputs and one to four counters. Standard counter types A, B, C, D, E and Z may be combined with a user-defined type on the module.

The module belongs in an RX3i Universal Backplane. Configuration, terminal-block revision and the counter-to-I/O assignment must be preserved as one controlled engineering record.

02
MANUFACTURER DATA

Technical Data

Manufacturer
Emerson
Exact model
IC695HSC304
Product family
PACSystems RX3i
Module type
High-speed counter
Counter capacity
1 to 4 counters
Maximum published count rate
1.5 MHz
Physical inputs
8 high-speed inputs
Physical outputs
7 high-speed outputs
Supported standard counter types
A, B, C, D, E and Z
Input voltage families
5 VDC or 12–24 VDC nominal
Output voltage range
4.7 to 40 VDC
Backplane requirement
RX3i Universal Backplane
03
ENGINEERING VIEW

Functions & Characteristics

A

Flexible counter architecture

Multiple standard counter modes and a user-defined mode can be assigned within the module.

B

Fast field interface

Eight inputs and seven outputs support encoder, strobe and setpoint arrangements documented by the machine design.

C

Diagnostic visibility

Module, field, terminal-block and point-state indications assist controlled commissioning.

D

Configuration-led maintenance

Counter types, setpoints, interrupts and I/O mapping are captured before hardware exchange.

04
FIELD USE

Applications

FIELD CONTEXT

Encoder and event counting

Collecting fast pulse trains where normal controller scan timing is insufficient.

FIELD CONTEXT

Programmable limit functions

Driving documented setpoint outputs from counter position or accumulated value.

FIELD CONTEXT

Pulse-width and interrupt tasks

Supporting time-critical measurements and configured I/O interrupt behavior.

05
CONTROLLED WORK

Service Control

Archive the counter map

Save counter types, input assignments, output setpoints, interrupts and controller references for IC695HSC304.

Check the terminal path

Confirm the approved 36-point terminal assembly revision, field voltage and shield termination.

Prove every mode

Exercise each configured counter, strobe, interrupt and output path before returning the machine to service.

IndustryParts industrial automation supply support
DOCUMENTED INDUSTRIAL SUPPLY

About IndustryParts

https://www.industryparts.com/

Traceable handling for IC695HSC304

IndustryParts keeps the complete model label, requested quantity, application evidence and delivery record together so the proposed supply can be checked against the installed system before dispatch.

Exact identity retained
Application evidence reviewed
Packing record kept traceable
07
CUSTOMER QUESTIONS

FAQ

Q01

How many counters can IC695HSC304 operate?

Emerson documents one to four counters for this module, depending on the selected counter types and I/O assignment.

Q02

What project evidence is essential for a IC695HSC304 spare?

Provide the Machine Edition configuration, counter modes, I/O map, setpoints, terminal-block identity and field-voltage record.

Q03

Why must the terminal assembly be checked for IC695HSC304?

Release-specific Emerson information identifies approved terminal-block revisions; an earlier block can create a mechanical or electrical mismatch.

Q04

Can IC695HSC304 be selected from the 1.5 MHz rating alone?

No. Counter mode, input voltage, output loading, interrupt use and backplane compatibility must also match.

Q05

What proves IC695HSC304 is ready after service?

Run controlled pulse tests for every configured counter and verify strobes, interrupts, setpoint outputs, diagnostics and controller values.

You May Also Like