Home>DCS>Yokogawa PH8EFP-05-TN-TT1-N-E General-Purpose pH Sensor Assembly

Hot Categories

Yokogawa PH8EFP-05-TN-TT1-N-E General-Purpose pH Sensor Assembly

Yokogawa PH8EFP-05-TN-TT1-N-E General-Purpose pH Sensor Assembly

Item NO.: 3805170

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa PH8EFP-05-TN-TT1-N-E General-Purpose pH Sensor Assembly
  • Item NO.3805170
  • Weight0.3000 kg = 0.6614 lb = 10.5822 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-22
INDUSTRIAL COMPONENT DOSSIERPH8EFP KCl Filling pH Sensor
KCL FILLING SENSOR · TITANIUM SOLUTION GROUND · TT1 RESERVE TANK

Yokogawa PH8EFP-05-TN-TT1-N-E General-Purpose pH Sensor Assembly

A Yokogawa KCl-filling pH sensor with a 5 m lead, titanium solution ground and TT1 general-purpose reserve tank.

MANUFACTURERYokogawa
EXACT MODELPH8EFP-05-TN-TT1-N-E
PRODUCT TYPEGeneral-Purpose pH Sensor Assembly
Official code checkTT1 uses digit 1
Lead length5 m
Analyzer terminationPin terminals
01
PRODUCT DOSSIER

Product Profile

Yokogawa PH8EFP-05-TN-TT1-N-E is a PH8EFP KCl-filling pH sensor assembly. The -05 code specifies a 5 m cable and tube, while -TN identifies a titanium solution ground.

Yokogawa lists TT1, with the digit 1, for the general-purpose KCl reserve tank. The originally submitted TTI spelling has therefore been normalized to the manufacturer code shown on this page.

The -E termination uses pin terminals for supported FLXA402, FLXA402T, FLXA202 and FLXA21 arrangements. Analyzer isolation and installation details must follow the applicable Yokogawa manual.

02
MANUFACTURER DATA

Technical Data

Manufacturer
Yokogawa
Exact model
PH8EFP-05-TN-TT1-N-E
Submitted reference
PH8EFP-05-TN-TTI-N-E
Sensor type
KCl-filling pH sensor
Cable and tube length
5 m
Solution ground
Titanium
KCl reserve tank
TT1 general-purpose tank
Analyzer termination
Pin terminals
Supported analyzer family
FLXA402 / FLXA402T / FLXA202 / FLXA21
Temperature element
Pt1000
Measurement pressure
Atmospheric to 10 kPa for general-purpose tank
Tank accessories
50A pipe bracket and KCl solution
03
SYSTEM PATH

System Role

INPUT RECORD

Verify

Confirm PH8EFP-05-TN-TT1-N-E, TT1 tank marking, analyzer type, insertion assembly and process pressure.

CONTROLLED ITEM

PH8EFP-05-TN-TT1-N-E

Keep the sensor hydrated, route the 5 m cable and tube without strain and mount the reserve tank correctly.

FIELD PROOF

Commission

Inspect electrolyte flow, enter approved calibration data and document slope, zero, temperature and stable process response.

04
MATCH CONTROL

Compatibility

✓

Complete ordering-code clarity

Each suffix controls a physical or connection detail, including the TT1 tank code.

✓

Integrated temperature element

Pt1000 supports the documented analyzer compensation path.

✓

Titanium solution ground

The TN execution identifies the solution-ground material.

✓

Analyzer-ready termination

The E suffix provides pin terminals for the stated FLXA analyzer families.

05
FIELD CONTEXT

Applications

APPLICATION

General process pH

KCl-filling pH measurement within the stated tank-pressure boundary.

APPLICATION

FLXA analyzer loops

Connection to the supported Yokogawa FLXA analyzer family using pin terminals.

APPLICATION

Exact assembly replacement

Matching lead length, solution ground, tank, pressure and analyzer connection before exchange.

INDUSTRIAL AUTOMATION SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Documented handling for PH8EFP-05-TN-TT1-N-E

IndustryParts keeps the exact model, requested quantity, installed-system evidence and delivery record together so the proposed supply can be checked against the real application before dispatch.

Exact label retained
Application evidence reviewed
Packing record kept traceable
IndustryParts industrial automation support team
06
PROCUREMENT SUPPORT

FAQ

Q01

Why does PH8EFP-05-TN-TT1-N-E use TT1 rather than TTI?

Yokogawa lists TT1 with the digit 1 as the general-purpose KCl reserve-tank code; TTI is not the published suffix.

Q02

What lead length is supplied with PH8EFP-05-TN-TT1-N-E?

The -05 code specifies a 5 m cable and KCl tube.

Q03

Which solution-ground material is used in PH8EFP-05-TN-TT1-N-E?

The TN suffix identifies a titanium solution ground.

Q04

Which analyzer evidence should accompany a PH8EFP-05-TN-TT1-N-E enquiry?

Provide the FLXA analyzer model, sensor and tank labels, holder details, process conditions, cable route and quantity.

Q05

What proves PH8EFP-05-TN-TT1-N-E is ready after commissioning?

Record electrolyte condition, leak-free installation, stable temperature, accepted slope and zero, and agreement with the site calibration procedure.

You May Also Like