Yokogawa PH8EFP-05-TN-TT1-N-E General-Purpose pH Sensor Assembly
A Yokogawa KCl-filling pH sensor with a 5 m lead, titanium solution ground and TT1 general-purpose reserve tank.
Product Profile
Yokogawa PH8EFP-05-TN-TT1-N-E is a PH8EFP KCl-filling pH sensor assembly. The -05 code specifies a 5 m cable and tube, while -TN identifies a titanium solution ground.
Yokogawa lists TT1, with the digit 1, for the general-purpose KCl reserve tank. The originally submitted TTI spelling has therefore been normalized to the manufacturer code shown on this page.
The -E termination uses pin terminals for supported FLXA402, FLXA402T, FLXA202 and FLXA21 arrangements. Analyzer isolation and installation details must follow the applicable Yokogawa manual.
Technical Data
System Role
Verify
Confirm PH8EFP-05-TN-TT1-N-E, TT1 tank marking, analyzer type, insertion assembly and process pressure.
PH8EFP-05-TN-TT1-N-E
Keep the sensor hydrated, route the 5 m cable and tube without strain and mount the reserve tank correctly.
Commission
Inspect electrolyte flow, enter approved calibration data and document slope, zero, temperature and stable process response.
Compatibility
Complete ordering-code clarity
Each suffix controls a physical or connection detail, including the TT1 tank code.
Integrated temperature element
Pt1000 supports the documented analyzer compensation path.
Titanium solution ground
The TN execution identifies the solution-ground material.
Analyzer-ready termination
The E suffix provides pin terminals for the stated FLXA analyzer families.
Applications
General process pH
KCl-filling pH measurement within the stated tank-pressure boundary.
FLXA analyzer loops
Connection to the supported Yokogawa FLXA analyzer family using pin terminals.
Exact assembly replacement
Matching lead length, solution ground, tank, pressure and analyzer connection before exchange.
About IndustryParts
https://www.industryparts.com/Documented handling for PH8EFP-05-TN-TT1-N-E
IndustryParts keeps the exact model, requested quantity, installed-system evidence and delivery record together so the proposed supply can be checked against the real application before dispatch.
FAQ
Why does PH8EFP-05-TN-TT1-N-E use TT1 rather than TTI?
Yokogawa lists TT1 with the digit 1 as the general-purpose KCl reserve-tank code; TTI is not the published suffix.
What lead length is supplied with PH8EFP-05-TN-TT1-N-E?
The -05 code specifies a 5 m cable and KCl tube.
Which solution-ground material is used in PH8EFP-05-TN-TT1-N-E?
The TN suffix identifies a titanium solution ground.
Which analyzer evidence should accompany a PH8EFP-05-TN-TT1-N-E enquiry?
Provide the FLXA analyzer model, sensor and tank labels, holder details, process conditions, cable route and quantity.
What proves PH8EFP-05-TN-TT1-N-E is ready after commissioning?
Record electrolyte condition, leak-free installation, stable temperature, accepted slope and zero, and agreement with the site calibration procedure.